Results
=======

Products of the real processing chain, with per-band quality statistics and their
reading. Two validated end-to-end runs back this page; both consume the **Sentinel-2
MSI Synthetic Raw Data Generator**'s products as input.

L0 → L1B — real chain, persisted product
----------------------------------------

The generator's open-container L0 + calibration-database ADFs pushed through
``l0_decode → radiometric → enhancement → toa`` (``eopf == 2.8.1``, ``nominal`` mode,
``emit_reflectance``): a persisted **L1B TOA-reflectance** EOPF product.

.. figure:: _static/results/l1b_rgb.png
   :alt: L1B TOA reflectance quicklook (RGB = B04/B03/B02)
   :width: 60%

   L1B TOA reflectance, RGB = B04/B03/B02, per-channel 2–98 % percentile stretch.
   The demo scene is a flat field, so the stretch deliberately reveals the residual
   *texture*: per-column striping is the impressed PRNU pattern, the speckle is
   shot/read noise.

Per-band statistics (the pipeline's ``stats`` phase, the non-referential ALG-QA metrics
of ``msi_processor/common/metrics.py`` — SDD <5.4.1>; produced by the manual
``product-stats`` CI job, 2026-07-02):

.. list-table::
   :header-rows: 1

   * - Band
     - mean (reflectance)
     - std
     - variance
     - SNR (dB)
   * - B02
     - 0.1753
     - 0.0053
     - 0.000029
     - 30.3
   * - B03
     - 0.1888
     - 0.0066
     - 0.000044
     - 29.1
   * - B04
     - 0.1911
     - 0.0070
     - 0.000049
     - 28.7
   * - B08
     - 0.2648
     - 0.0094
     - 0.000089
     - 29.0
   * - B11
     - 0.0434
     - 0.0017
     - 0.000003
     - 28.3
   * - B12
     - 0.0535
     - 0.0019
     - 0.000004
     - 28.8

Reading the numbers
-------------------

* **Reflectance means** sit at the levels impressed by the generator's flat-field
  scene (≈ 0.19 VNIR / 0.27 NIR / 0.05 SWIR) — the absolute radiometric scale
  survives the full chain (DN → radiance → reflectance) unchanged.
* **SNR** is scene-limited, not instrument-limited: on a flat field the standard
  deviation *is* the residual instrument texture (uncorrected PRNU + noise), so the
  per-band SNR ranks the bands by their noise-model α/β and PRNU amplitude.
* **Variance** complements SNR as the raw second moment used by the QA stage
  (``ALG-QA-*``); both are computed product-side with no reference.

Validation status
-----------------

* The chain producing these numbers is CI-verified: 8 of 8 processing units
  implemented and green (see the :doc:`SUITR <compliance/suitr-unit-integration-test-report>`
  and the live :doc:`CI test report <suitr>`).
* A second, sharper end-to-end result — the real-L1A **bit-identity** run through
  ``l0_decode`` (L1A′ ≡ L1A, 13/13 bands) — is documented in the generator's
  validation pages and its qualification is summarised in the
  :doc:`QR report <compliance/qr-qualification-review-report>`.
* **AR-gated figures:** the *referential* accuracy metrics (L1B radiometric RMSE
  vs a calibrated reference — REQ-P-01 ``RAD_ACC``; geometric ``GEO_CE90`` /
  ``BAND_COREG`` — REQ-P-02; ``BOA_ACC`` — REQ-P-03) are validated on operator data
  at AR and are deliberately **not** quoted here (see the
  :doc:`V&V report <compliance/vv-report>`). the ``stats`` phase computes them
  once a reference product is available.

Reproduce
---------

Run the manual **pipeline-nominal** CI job (integration-tests stage): the repository's
single driver pulls the inputs from the shared ``ipf/data-store`` registry, runs
``l0-decode → radiometric → enhancement → toa → stats`` and artifacts the statistics
table. Locally (eopf environment): ``python scripts/run_pipeline.py <store>``;